SECTION VIII -ERROR MESSAGES & TROUBLESHOOTING
60
display, a message transaction is created, stored and sent to the Central
Controller when transactions are downloaded. If transaction storage space
becomes an issue, this system option may be disabled. If this option is
disabled however, please be aware that the second odometer entry made on
the keypad is accepted and written to the key without question.
** VEHICLE IS DUE FOR PREVENTATIVE **
** MAINTENANCE --INFORM SUPERVISOR! **
Preventative Maintenance (PM) due mileage encoded on key has been
reached. User is being notified that PM is due for this vehicle.
** HOSE HAS BEEN SHUT DOWN. **
** PLEASE ALERT SUPERVISOR! **
HOSE IS UNAVAILABLE FOR USE
Pulser has failed
Hose was activated equal to number of zero quantity setting in configuration
consecutively and no fuel dispenses.
Hose has been disabled by supervisor
** HOSE IS CURRENTLY IN USE ! **
** PLEASE SELECT ANOTHER. **
Hose number selected by user is being used or was in use and finish timer
has not expired.
** ALL AVAILABLE HOSES ARE IN USE ! **
All available hoses are being used or finish timers have not expired.
** PUMP HANDLE NOT TURNED OFF. **
** PLEASE TURN PUMP HANDLE OFF ! **
With the pump handle set to YES, the user is prompted that the pump handle
was turned on before the hose was selected and the user was prompted to
turn on the pump handle.