2.1.1 Installation Requirements
When installing the e1600 unit you must ensure that the screens of the co-axial cables are
connected to the earth of the building installation and that the unit is connected to a power socket-
outlet with a protective earthing connection.
2.1.2 Mains Power
The mains power can be between 100 VAC and 240 VAC; AC 50 / 60 Hz.
2.1.3 Video Inputs
The e1600 unit has 16 Composite Video Inputs. The Video Inputs are used to connect PAL or NTSC
video cameras. The unit will auto-detect the connected video sources.
2.1.4 Audio Inputs
The e1600 has 16 mono audio inputs these are arranged as 8 ‘stereo’ type 3.5mm connectors.
2.1.5 Video Outputs
The video outputs are currently not enabled on the e1600 encoder
2.1.6 Alarm Inputs
Up to 16 alarm inputs can be configured on the e1600.
Two common / GND signals per connector block are provided for your convenience. Wire Alarm
inputs in accordance with the below diagram: