126
SYSTem:FRST
Function
Restores factory default parameters. Refer to Table 3-5 & Table 3-6
NOTE:
Factory Reset does not affect advanced parallel configuration acknowledgment (does not affect
power supply configuration (Single, Master or Slave roles does not change).
SYSTem:FIRMware[:VERSion]?
Function Returns firmware versions string: Interface, Master Control, Display, and
Option (if available).
Return
<SRD> xx.xxx,xx.xx,x.x,<option name>:xx.xxx
NOTE:
Option firmware revision is seen if the query is sent through optional communication interface.
SYSTem:PANel:LOCK?
Query
Returns the front panel unlocked (0)/locked (1) state.
Return
<Bool> 0|1
SYSTem:PARallel?
Query
SYSTem:PARallel?
Return
<DSC> SING|Master+N|SLAVE
NOTE:
N represents the number of slave units connected.
SYSTem:PARallel:ACKNowledge
Function
Accept present parallel configuration.
SYSTem:PON:TIME?
Function Returns the total time Power Supply is connected to AC & Power Switch
is ON. Max value: 2
32
-1
Unit
minutes
Return
<NR1>
SYSTem:PON:TIME:AC?
Function Returns the total time Power Supply is connected to AC. Max value: 2
32
-
1.
Unit
minutes
Return
<NR1>