OVP <NR2>
Function Sets the Over-Voltage Protection level. An attempt to adjust from the front
panel or program the OVP below this level will result in the execution error
response (‘E04’) and the OVP setting will stay unchanged
Parameters Range is limited by the OVP programming range and voltage programmed
value. The OVP setting range is given in Table 5-6
OVM
Function Sets the Over-Voltage Protection to maximum. The OVP setting range is given in
UVL <NR2>
Function Sets the Under Voltage Limit. Value ‘n’ may be equal or less than 95% of PV
setting. Returns ‘E06’ if higher
Parameters Range is limited by the UVL programming range and voltage programmed value.
Refer to Table 5-7 for UVL programming range
UVP <Bool>
Enable/Disable Under Voltage Protection
AST<Bool>
Sets the auto-restart mode to ON or OFF
SAV <NR1>
Saves the Power Supply settings to a specific memory location
Parameters 1,2,3,4. SAV without a parameter stores the Power Supply settings in the
RCL <NR1>
Function Restores the Power Supply settings from a stored memory location (locations 1,
2, 3 or 4), previously stored by the SAV command
Parameters 1,2,3,4. RCL without a parameter restores the Power Supply settings stored in