66
If the rating has decimal point, substitute “P” for the decimal point.
For example:
Model
Default Hostname
G10-40
G10-40
GH100-4.5
GH100-4P5
A custom host name can be created through the web pages (refer to section 5.7.6.6).
For example, host name can be set to LAMBDA. In this case, the control program can send
commands to LAMBDA.
The Power Supply can detect if its host name is already in use by another device. This state is
called a host name conflict. In this case, the supply will make its host name unique by appending a
dash and a number (i.e. LAMBDA-2).
LAN Reset does not change the host name, even if it is a custom name, but it may remove the
dash and the number if a host name conflict has been removed.
To restore the factory default host name, open the LAN Modify web page and enter a blank for
the new host name (refer to section 5.7.6.6).
The Power Supply may be set to one of the three network modes, each with a different way to use
the host name. This is shown in the table below.
DHCP
Auto-IP
Static IP
Hostname
Default Hostname
xxxxvvvv-aaaa (Refer to
the above example)
xxxxvvvv-aaaa (Refer to
the above example)
None, hostname cannot be
used
Hostname Protocol Hostname by NetBIOS or
DNS
Hostname by NetBIOS or
DNS
None, hostname cannot be
used
Hostname on Web
Pages
Shows Host name on the
Home page and on the
LAN Configure page
Shows Host name on the
Home page and on the
LAN Configure page
Shows Host name on the Home
page and on the LAN Configure
page
5.7.4.6 Description and DNS Service Names
On the Power Supply web page, the Description field is also the DNS-SD service name.
The factory default description is:
< Manufacturer> <Product > < last 3 digits of serial number >
Example: TDK-LAMBDA Supply 123
The Power Supply can detect if its service name (description) is already in use by another device.
This is called a service name conflict. In this case, the supply will change its service name to a
unique name by appending a number in brackets to it.
For example, its service name will become TDK-LAMBDA Supply 123 (2).