107
5.14.2 Initiate Subsystem
INITiate[:IMMediate]
Function Initialize trigger system.
If initialized, trigger in system is active (system is ready to receive trigger
signal).
If not initialized, all trigger signals are ignored.
INITiate:CONTinuous <Bool>
Function Continously re-initiates a trigger.
If inactive, the trigger system must be re-initiated for each trigger by the
INITiate command.
Parameters
0|1, OFF|ON
Query
INITiate:CONTinuous?
Return
<Bool> 0|1
NOTE:
When Power Supply is in the INIT state, it is impossible to change any sequence programming
parameter. Send ABORt commands to allow parameters change.
5.14.3 Instrument Subsystem
INSTrument:COUPle <DSC>
Function Defines the coupling between various Power Supplies.
All coupled power supplies receive communication commands.
Parameters
NONE|ALL
NOTE:
INSTrument:COUPle <DSC> command preserves power supply selection command. The unit
selected by INSTrument:[N]SELect command is the only unit which will reply to query commands.
INSTrument:[N]SELect <NR1>
Function
Enables communication with the addressed Power Supply.
Parameters
0 ~ 31
Query
INSTrument:[N]SELect?
Return
From 0 up to 31
5.14.4 Global Subsystem
Global Commands General
Power Supplies acting upon Global Commands don’t have to be addressed.
All Power Supplies attached to the Interface must be capable of accepting Global Commands.
Global commands have no reply, execution only.