124
5.14.10 SYSTem Subsystem
SYSTem[:COMMunicate]:ADDRess <NR1>
Sets the Power Supply communication address.
SYSTem[:COMMunicate]:ADDRess?
NOTE:
Power Supply addressing is lost after an address change.
SYSTem[:COMMunicate]:BAUDrate <DSC>
Sets a serial communication Baud Rate (including multi-drop).
9600|19200|38400|57600|115200 or 0|1|2|3|4
SYSTem[:COMMunicate]: BAUDrate?
<NR1> 9600, 19200, 38400, 57600, 115200
SYSTem[:COMMunicate]:INTerface <DSC>
Function Sets a communication interface.
The Power Supply addressing is lost after the communication interface
0|1|2|3|4, RS232|RS485|LAN|USB|OPTion
SYSTem[:COMMunicate]:INTerface?
<DSC> RS232, RS485, LAN, USB, OPT
SYSTem[:COMMunicate]:LAN:HOST?
Reads hostname. LAN specific command.
<SRD> up to 15 characters long
NOTES:
<X> represents a running number (1, 2, 3, etc…) according to the number of Power Supplies from
the same type.
A number is added only if at least 2 Power Supplies of the same type are connected to the same
network.