125
SYSTem[:COMMunicate]:LAN:IDLED <Bool>
Function
Blink Display & green LXI LED. LAN specific command.
Parameters
0|1, OFF|ON
SYSTem[:COMMunicate]:LAN:IP <SRD>
Function
Sets a LAN IP address. LAN specific command.
Parameters
xxx.xxx.xxx.xxx
Query
SYSTem[:COMMunicate]:LAN:IP?
Return
<SRD> xxx.xxx.xxx.xxx
Example
192.200.0.10; 192.9.33.110 (No zeros padding)
SYSTem[:COMMunicate]:LAN:MAC?
Query
SYSTem[:COMMunicate]:LAN:MAC? LAN specific command.
Return
<SRD> xx:xx:xx:xx:xx:xx (hexa-decimal)
Example
A0:12:34:FF:01:6D
SYSTem[:COMMunicate]:LAN:RESet
Function Sets LAN parameters to default.
Refer to factory reset LAN settings,
Table 3-6: LAN Non-Volatile Memory
Parameters.
SYSTem[:COMMunicate]:LANGuage GEN
Function Sets the communication protocol to GEN language.
GEN language is available in RS232/485 and USB.
Query
SYSTem[:COMMunicate]:LANGuage?
Return
<DSC> SCPI
SYSTem:ERRor:ENABle
Function
Enables log of last 10 Error messages.
SYSTem:ERRor?
Query Returns an error number and a corresponding error message stored in an
error queue. Works as FIFO. When no error exists 0,”No error” is returned.
If Buffer reaches above 10 messages, the command returns “-350, Queue
Overflow”.
Return
<SRD>
Example
0,”No error”