97
FLT?
Query Returns the value of the Questionable Group Condition register, a read-only
register holding the real-time Power Supply faults.
Returns
<NRh>
Example
09FA
FENA <NRh>
Function Sets the value of the Questionable Group Enable register. This register is a mask
to enable specific bits from the Condition register to the Event register.
Parameters
0…FFFF
Query
FENA?
Returns
<NRh> 0…FFFF
FEVE? <NRh>
Query Returns the value of the Questionable Group Event register, which is a read-only
register.
Fault Events are updated as a transition from 0 to 1. Reading the register clears it
(All Zeros).
Returns
<NRh>
STAT?
Query Returns the value of the Operation Group Condition register, which is a read-
only register that holds the real-time status of the Power Supply.
Returns
<NRh>
Example
09FA
SENA <NRh>
Function Sets the value of the Operation Group Enable register. This register is a mask to
enable specific bits from the Condition register to the Event register.
Parameters
0…FFFF
Query
SENA?
Returns
<NRh> 0…FFFF
SEVE? <NRh>
Query Returns the value of the Operation Group Event register, which is a read-only
register.
Fault Events are updated as a transition from 0 to 1. Reading the register clears it
(All Zeros).
Returns
<NRh>