156
Error Number
Error Description
Error Event
335 “Internal Resistance is ON” An attempt to set Constant Power Mode, Analog Programming, Slew
Rate or Sequencer while Internal Resistance is ON
336 “Constant Power Mode is
ON”
An attempt to set Internal Resistance, Analog Programming, Slew
Rate or Sequencer while Constant Power Mode is ON
337 “Analog Mode is ON An attempt to set Constant Power Mode, Internal Resistance, Slew
Rate or Sequencer while Analog Programming is ON
338 “Slew Mode is ON” An attempt to set Constant Power Mode, Internal Resistance, Analog
Programming or Sequencer while Slew rate is ON
340 "Advanced Parallel Wait
Acknowledge"
Advanced Parallel Waiting for Acknowledge, system has changed
341
“Input Overflow”
Received over 1500 characters
-400
“Query Error”
Generic query error
Table 7-5: SCPI Error Messages
NOTE
If there is no error, SYSTem:ERRor? query returns 0,”No Error”. Power supply address is
excluded.