TECDrive20-EU Series Inverter Function parameters
-50-
Function
code
Name
Description
Default
Modify
0: Torque control is invalid
1: Set via keypadP3.12
2: Set via AI1
3: Set via AI2
4: Set via AI3
5: Set via pulse frequency HDI
6: Multi-step torque setting
7: Set via Modbus communication
810: Reserved
Note: Setting mode 27, 100% corresponds to 3
times of the motor rated current
P03.12
Keypad setting
torque
Setting range: -300.0%300.0% (motor rated
current)
50.0%
P03.13
Torque
reference filter
time
0.00010.000s
0.100s
P03.14
Setting source
of upper-limit
frequency of
forward
rotation in
torque control
0: Set via keypad (P03.16 sets P03.14, P03.17
sets P03.15)
1: Set via AI1
2: Set via AI2
3: Set via AI3
4: Set via pulse frequency HDI
5: Set via multi-step
6: Set via Modbus communication
79: Reserved
Note: setting method 19, 100% corresponds to
the maximum frequency
0
P03.15
Setting source
of upper-limit
frequency of
reverse
rotation in
torque control
0
P03.16
Torque control
forward
rotation
upper-limit
frequency
keypad limit
value
This function is used to set the upper limit of the
frequency. P03.16 sets the value of P03.14;
P03.17 sets the value of P03.15.
Setting range: 0.00 HzP00.03 (the max. output
frequency)
50.00
Hz
P03.17
Torque control
reverse
rotation
upper-limit
frequency
50.00
Hz