TECDrive20-EU Series Inverter Function parameters
-87-
Function
code
Name
Description
Default
Modify
P09.18
Low frequency
integral time
(Ti)
0.0010.00s
0.10s
P09.19
Low frequency
differential time
(Td)
0.0010.00s
0.00s
P09.20
Low point
frequency of
PID parameter
switching
0.00HzP09.21
When the ramp frequency is no greater than
P09.20, current PID parameters are
P09.17P09.19. When the ramp frequency is no
less than P09.21, current PID parameters are
P09.04P09.06. The medium frequency range is
the linear interpolation values between the two
PID parameter groups.
5.00Hz
P09.21
High point
frequency of
PID parameter
switching
P09.20P00.03
10.00Hz
P10 group Simple PLC and multi-step speed control
Function
code
Name
Description
Default
Modify
P10.00
Simple PLC
mode
0: Stop after running once; the inverter stops
automatically after running for one cycle, and it
can be started only after receiving running
command.
1: Keep running in the final value after running
once. The inverter keeps the running frequency
and direction of the last section after a single
cycle.
2: Cyclic running; the inverter enters the next
cycle after completing one cycle until receiving
stop command and stops.
0
P10.01
Simple PLC
memory
selection
0: No memory after power-off
1: Memory after power-off; PLC memories its
running step and frequency before power-off.
0