TECDrive20-EU Series Inverter Function parameters
-52-
Function
code
Name
Description
Default
Modify
Flux weakening
coefficient of the motor
Min. limit
0.10
1.00
2.00
m
Setting range of P03.22: 0.12.0
Setting range of P03.23: 10%100%
P03.24
Max. voltage
limit
This parameter sets the max. voltage of the
inverter, which is dependent on the site situation.
Setting range: 0.0120.0%
100.0%
P03.25
Pre-exciting
time
Pre-activate the motor when the inverter starts
up. Build up a magnetic field inside the motor to
improve the torque performance during the
starting process.
The setting time: 0.00010.000s
0.300s
P03.26
Flux
weakening
proportional
gain
08000
1200
P03.27
Speed
display
selection of
vector control
0: Display as per the actual value
1: Display as per the setting value
0
P03.28
Static friction
compensation
coefficient
0.0100.0%
0.0%
P03.29
Dynamic
friction
compensation
coefficient
0.0100.0%
0.0%