EasyManua.ls Logo

Technogym Spazio Forma - T He Display Shows E 3

Technogym Spazio Forma
136 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SPAZIO FORMA: Service & Maintenance manual - rev. 1.0
Page 6.10
6.4. THE DISPLAY SHOWS “E 3”
The machine displays this message if:
it has detected a failure to actuate movement of the belt motor at the start of the training session;
the movement of the belt motor is interrupted during the training session;
the power supply to the inverter is cut off by the power isolating board.
The most common causes are principally:
One of the motor thermal cutouts has been tripped;
The inverter has shut down for protection from a mains voltage fluctuation (spike or glitch).
In both cases it is recommended to turn off the machine for at least one hour in the first case, and for
a few minutes in the second case before resuming normal operation.
If the machine still does not operate correctly, follow the procedures (which differ depending on the
inverter model used) set out in the following paragraphs.
THE DISPLAY
SHOWS "E 3"
Check the error message
display ed and/or
memorized by the inv erter
E01-E02-E03-E04-E05
E06-E07
E08-E10-E11-E22
E09
E12
E14
E15
E21
None
INVERTER OFF
The following paragraphs describe the troubleshooting procedures associated with the individual
errors.