EasyManua.ls Logo

TECO speecon 7200ma - Page 103

TECO speecon 7200ma
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
101
Parameter
No.
Name
LCD display
(English)
Unit Description
Multi-function
Analog Output Level
Un-13
Amount of PG
Speed Feedback
Un-13= 100.0%
PG Feedback.
0.1%
100.0%=MAX. output
frequency
10V/MAX. Out
p
ut
Frequency
Un-14
Amount of PG
Speed Compen.
Un-14= 100.0%
PG Compen.
0.1% 100.0%=MAX. output freq.
10V/MAX. Out
p
ut
Frequency
Un-15
PID Control Input
Un-15= 100%
PID Input
0.1% 100.0%=MAX. output freq.
10V/Max. output
frequency
Un-16
PID Control
Output 1
Un-16= 100%
PID Output1
0.1% 100.0%=MAX. output freq.
10V/Max. output
frequency
Un-17
PID Control
Output 2
Un-17= 00%
PID Output2
0.1% 100.0%=MAX. output freq.
10V/Max. output
frequency
Un-18 Fault Message 1
Overcurrent
Message1
Fault message occurred now
Un-19 Fault Message 2
Overcurrent
Message2
Fault message occurred
last time
Un-20 Fault Message 3
Overheat
Message3
Fault message occurred
last two time
Un-21 Fault Message 4
Overtorque
Message4
Fault message occurred
last three time
Un-22
The Parameter
Of Time Period
Between Last
Fault And The
Nearest Fault.
Un-22= 2400Hr
Last Fault Run Time
1Hr
The value of ‘Run Elapse
Time’ parameter will be
cleared after fault has been
cleared.
Un-23
Frequency
Command While
Fault Occurred
Un-23= 60.00Hz
Last Fault Freq.Cmd.
0.01Hz --
Un-24
Output Freq.
While Fault Occurred
Un-24= 60.00Hz
Last Fault O/P Freq.
0.01Hz --
Un-25
Output Current
While Fault Occurred
Un-25= 12.5A
Last Fault O/P I
0.1A --
Un-26
Output Voltage
While Fault Occurred
Un-26= 220.0V
Last Fault O/P V
0.1V --
Un-27
DC Volta
g
e
While
Fault Occurred
Un-27= 310.0V
Last Fault O/P V
0.1V --
Un-28
I/P Terminal
Status While
Fault Occurred
Un-28= 00000000
Last Fault I/P Term.
Same as Un-11,
display terminal status
Un-29
O/P Terminal
Status While
Fault Occurred
Un-29= 00000000
Last Fault O/P Term.
Same as Un-12,
display terminal status
Un-30
Time Elapsed
After Power-On
Un-31= 00002Hr
P Elapsed Time
1Hr
Display total time elapsed
after power ON
Un-31
Time Elapsed
After Run
Un-31= 00002Hr
R Elapsed Time
1Hr
Display total time elapsed
after pressing RUN
Un-32
EPROM S/W
Vers io n
Un-32= 00001
Soft Number
-Manufacturing use-
Un-33
Feedback
Motor Speed
Un-33= 00000r
p
m
Motor Speed
1rpm
Display motor speed while PG
feedback is set.
10V/MAX. Motor
Speed

Table of Contents

Related product manuals