EasyManua.ls Logo

TECO speecon 7200ma - Terminal Functions; Main Circuit Terminals

TECO speecon 7200ma
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12
1.5 Description of terminal function
Table 1 Main circuit terminals
Terminal Terminal Function
R/L1
S/L2
T/L3
Main circuit input power supply
(For single phase power supply, please use R/L1, S/L2 as input terminal)
Θ
B1/P
B2/R
B2
B1/P, B2: External braking resistor
B1/P, Θ: DC power supply input
U/T1
V/T2
W/T3
Inverter output
E
Grounding lead (3rd type grounding)
Terminal block configuration
For Compact Size Type 220V : 1-2HP, 440V : 1-2HP
JNTMBGBB□□□□JKS
1 JNTMBGBB□□□□AZS
1
JNTMBGBB□□□□JKSU1 JNTMBGBB□□□□AZSU1
B1/P
B2
R/
L1
S/
L2
T/
L3
U/
T1
V/
T2
W/
T3
For Standard type and UL(CUL) Type Series
JNTMBGBB□□□□JK
--
1 JNTMBGBB□□□□AZ
--
1
JNTMBGBB□□□□JK
U1 JNTMBGBB□□□□AZ
U1
JNTMBGBB□□□□JKA
1 JNTMBGBB□□□□AZA
1
JNTMBGBB□□□□JKAU1 JNTMBGBB□□□□AZAU1
220V : 3 ~ 5 HP, 440V : 3 ~ 5 HP
220V : 7.5 ~ 10 HP, 440V : 7.5 ~ 10 HP
Power In
E
B1/P
B2
B1/RR/
L1
S/
L2
T/
L3
U/
T1
V/
T2
W/
T3
Dynamic brake
To Motor
CHARGE
Power In
E
B1/P
B2
B1/RR/
L1
S/
L2
T/
L3
U/
T1
V/
T2
W/
T3
Dynamic brake
To Motor
E
CHARGE
220V : 15 ~ 20 HP, 440V : 15 ~ 20 HP
Power In
B1/P
B2
R/
L1
S/
L2
T/
L3
U/
T1
V/
T2
W/
T3
Dynamic brake
To Motor

Table of Contents