24
Noise filter
A. INPUT SIDE NOISE FILTER
Installing a noise filter on power supply side to eliminate noise transmitted
between the power line and the inverter
7200MA has its specified noise filter to meet the EN55011 class A
specification
Table 6 Noise filter on the input side
Inverter Model Noise filter
VHP
Rated
current
φ
Code Rated current
Dimension
1
φ
JUNF12015S-MA 15 A fig. (a)
1 4.8A
3
φ
JUNF32012S-MA 12 A fig. (a)
1
φ
JUNF12015S-MA 15 A fig. (a)
2 6.5A
3
φ
JUNF32012S-MA 12 A fig. (a)
1
φ
JUNF12020S-MA 20 A fig. (a)
220V
1
φ
/3
φ
3 9.6A
3
φ
JUNF32024S-MA 24 A fig. (a)
5.4 17.5A 3
φ
JUNF32024S-MA 24 A fig. (a)
7.5 24A 3
φ
JUNF32048S-MA 48 A fig. (b)
10 32A 3
φ
JUNF32048S-MA 48 A fig. (b)
15 48A 3
φ
JUNF32070S-MA 70 A fig. (b)
220V
3
φ
20 64A 3
φ
JUNF32070S-MA 70 A fig. (b)
1 2.6A 3
φ
JUNF34008S-MA 8 A fig. (a)
24A3
φ
JUNF34008S-MA 8 A fig. (a)
3 4.8A 3
φ
JUNF34012S-MA 12 A fig. (a)
5.4 8.7A 3
φ
JUNF34012S-MA 12 A fig. (a)
7.5 12A 3
φ
JUNF34024S-MA 24 A fig. (b)
10 15A 3
φ
JUNF34024S-MA 24 A fig. (b)
15 24A 3
φ
JUNF34048S-MA 48 A fig. (b)
440V
3
φ
20 32A 3
φ
JUNF34048S-MA 48 A fig. (b)
Dimension : (unit : mm)
125
140
40
80
2 −
φ
6.5


60
L1 L2 L3
L1 L2 L3
LINE
LOAD
PE
PE










L1 L2 L3
L1 L2 L3
LINE
LOAD
PE
PE












225
250
50
100
4 −
φ
6.5
70


fig. 7(a) fig. 7(b)