27
Analog operator
All 7200MA have the digital LCD digital operator. Moreover, an analog operator
as JNEP-16 (shown in fig. 9) is also available and can be connected through wire as
a portable operator. The wiring diagram is shown below.
R/L1
BREAKER
FWD RUN
STOP
SC
15V Power Supply
for Speed Ref
.
(+15V, 20 mA)
GND 0V
VIN Master Speed
0 ~ 10V
2k
Master Freq. Ref.
976
, 1/4 W
A01
GND
FM
B1/P
B2
IM

RA
RB
RC
Multi-Function
Contact Output
250V AC, max. 1A
30V DC, max. 1A
DO1
DOG
DO2
Multi-Function
Output 1, 2
(Open Collector
48V/50mA)
During
Running
Speed
Agree
7200MA
Analog Operator
(JNEP-16)
1
S/L2
T/L3
R/L1
S/L2
T/L3
U/T1
V/T2
W/T3
ANALOG
OUTPUT
Fig. 9 Analog Operator
PROFIBUS Communication Card
Code No. : 4H300D0290009
Please refer to the appendix D and “7200MA PROFIBUS-DP Communication
Application manual” for communication interface.

Table of Contents