36
3.2 Parameters Groups Can Be Changed during Running Bn-□□
Under the DRIVE mode, the Parameter group can be monitored and set by the users.
Function
Parameter
No.
Name LCD display (English) Setting range
Setting
Unit
Factory
Setting
Ref.
Page
Bn-01 Acceleration Time 1
Bn-01= 0010.0s
Acc. Time 1
0.0∼6000.0s 0.1s 10.0s
Bn-02 Deceleration Time 1
Bn-02= 0010.0s
Dec. Time 1
0.0∼6000.0s 0.1s 10.0s
Bn-03 Acceleration Time 2
Bn-03= 0010.0s
Acc. Time 2
0.0∼6000.0s 0.1s 10.0s
Acc/Dec
time
Bn-04 Deceleration Time 2
Bn-04= 0010.0s
Dec. Time 2
0.0∼6000.0s 0.1s 10.0s
39
Bn-05
Analog Frequency
Cmd. Gain (Voltage)
Bn-05= 0100.0%
Voltage Cmd. Gain
0.0∼1000.0% 0.1% 100.0%
Bn-06
Analog Frequency
Cmd. Bias (Voltage)
Bn-06= 000.0%
Voltage Cmd. Bias
-100.0%∼100.0%
0.1% 0.0%
Bn-07
Analog Frequency
Cmd Gain. (Current)
Bn-07= 0100.0%
Current Cmd. Gain
0.0∼1000.0% 0.1% 100.0%
Analog
Frequency
Bn-08
Analog Frequency
Cmd Bias (Current)
Bn-08= 000.0%
Current Cmd. Bias
-100.0%∼100.0%
0.1% 0.0%
39
Bn-09
Multi-Function
Analog Input Gain
Bn-09= 0100.0%
Multi_Fun. ~Gain
0.0∼1000.0% 0.1% 100.0%
Multi-
Function
Analog
Input
Bn-10
Multi-Function
Analog Input Bias
Bn-10= 000.0%
Multi_Fun. ~Bias
-100.0%∼100.0%
0.1% 0.0%
39
Torque
Boost
Bn-11
Auto Torque Boost
Gain
Bn-11= 0.5
Auto_Boost Gain
0.0∼2.0 0.1 0.5 40
Bn-12 Monitor 1
Bn-12= 01
Display: Freq.Cmd.
1∼18 1 1
Monitor
Bn-13 Monitor 2
Bn-13= 02
Display: O/P Freq.
1∼18 1 2
41
Bn-14
Multi-Function Analog
Output AO1 Gain
Bn-14= 1.00
~Output AO1 Gain
0.01∼2.55 0.01 1.00
Multi-
Function
Analog
Output
Bn-15
Multi-Function Analog
Output AO2 Gain
Bn-15= 1.00
~Output AO2 Gain
0.01∼2.55 0.01 1.00
42
Bn-16 PID Detection Gain
Bn-16= 01.00
PID Cmd. Gain
0.01∼10.00 0.01 1.00
Bn-17
PID Proportional
Gain
Bn-17= 01.00
PID P_gain
0.01∼10.00 0.01 1.00
PID
Control
Bn-18 PID integral time
Bn-18= 10.00s
PID I_Time
0.00∼100.00s 0.01s 10.00s
42