EasyManua.ls Logo

Tektronix AFG3000 Series - Source[1|2]]:Pulse:period; Source[1|2]]:Pulse:transition[:Leading]

Tektronix AFG3000 Series
230 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Syntax and Commands
AFG3000 Series Arbitrary/Function Generators Reference Manual 3-69
[SOURce[1|2]]:PULSe:PERiod
This command sets or queries the period for pulse waveform.
Group
Source
Syntax
[SOURce[1|2]]:PULSe:PERiod {<period>|MINimum|MAXimum}
[SOURce[1|2]]:PULSe:PERiod?{MINimum|MAXimum}
Arguments
<period>::=<NRf>[<units>]
where
<NRf> is the pulse period.
<units>::=[ns | µs | ms | s]
Returns
<period>
Examples
SOURce1:PULSe:PERiod 200ns
sets the CH 1 pulse period to 200 ns.
[SOURce[1|2]]:PULSe:TRANsition[:LEADing]
This command sets or queries the leading edge time of pulse waveform.
Group
Source
Syntax
[SOURce[1|2]]:PULSe:TRANsition[:LEADing] {<seconds>|MINimum|
MAXimum}
[SOURce[1|2]]:PULSe:TRANsition[:LEADing]?{MINimum|MAXimum}
Arguments
<seconds>::=<NRf>[<units>]
where
<NRf> is the leading edge time of pulse waveform.
<units>::=[ns | µs | ms | s]
Returns
<seconds>
Examples
SOURce1:PULSe:TRANsition:LEADing 200ns
sets the CH 1 leading edge time to 200 ns.