Syntax and Commands
3-100 AFG3000 Series Arbitrary/Function Generators Reference Manual
TRACe|DATA[:DATA]:LINE (No Query Form)
This command writes line data to the edit memory. The data between the specified
points is interpolated linearly.
Group
Trace
Syntax
TRACe|DATA[:DATA]:LINE EMEMory,<start_point>,<point_data1>,
<end_point>,<point_data2>
Arguments
<start_point>::=<NR1>
where <NR1> is the first point from which the data is interpolated linearly.
<point_data1>::=<NR1>
where <NR1> is the data value at the start point.
<end_point>::=<NR1>
where <NR1> is the last point from which the data is interpolated linearly.
<point_data2>::=<NR1>
where <NR1> is the data value at the end point.
Examples
DATA:DATA:LINE EMEMory,1,2047,250,4094
sets a data value of 2047 for start point 1 and a data value of 4094 for end point 250,
and interpolates linearly between these two points in the edit memory.

Table of Contents

Other manuals for Tektronix AFG3000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix AFG3000 Series and is the answer not in the manual?

Tektronix AFG3000 Series Specifications

General IconGeneral
BrandTektronix
ModelAFG3000 Series
CategoryPortable Generator
LanguageEnglish

Related product manuals