Syntax and Commands
AFG3000 Series Arbitrary/Function Generators Reference Manual 3-101
TRACe|DATA[:DATA]:VALue
This command sets or queries the data value at the specified point in the edit
memory.
Group
Trace
Syntax
TRACe|DATA[:DATA]:VALue EMEMory,<point>,<data>
TRACe|DATA[:DATA]:VALue? EMEMory,<points>
Arguments
<point>::=<NR1>
where <NR1> is the specified point number in the edit memory.
<data>::=<NR1>
where <NR1> is the data value for the specified point number.
Returns
<NR1>
Examples
DATA:DATA:VALue EMEMory,500,2047
sets the data value to 2047 for the point number 500 in the edit memory.
DATA:DATA:VALue? EMEMory,500
might return “2047”
This example indicates that the data value of point number 500 is set to 2047.