EasyManua.ls Logo

Texas Instruments CC1101 - Page 10

Texas Instruments CC1101
106 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CC1101
SWRS061H Page 10 of 98
Table 4: Current Consumption
Parameter
Min
Typ
Max
Unit
Condition
Current consumption,
433 MHz
16.0
mA
Receive mode, 1.2 kBaud, register settings optimized for reduced
current, input at sensitivity limit
15.0
mA
Receive mode, 1.2 kBaud, register settings optimized for reduced
current, input well above sensitivity limit
15.7
mA
Receive mode, 38.4 kBaud, register settings optimized for
reduced current, input at sensitivity limit
15.0
mA
Receive mode, 38.4 kBaud, register settings optimized for
reduced current, input well above sensitivity limit
17.1
mA
Receive mode, 250 kBaud, register settings optimized for
reduced current, input at sensitivity limit
15.7
mA
Receive mode, 250 kBaud, register settings optimized for
reduced current, input well above sensitivity limit
29.2
mA
Transmit mode, +10 dBm output power
16.0
mA
Transmit mode, 0 dBm output power
13.1
mA
Transmit mode, 6 dBm output power
Current consumption,
868/915 MHz
15.7
mA
Receive mode, 1.2 kBaud, register settings optimized for
reduced current, input at sensitivity limit.
See Figure 3 for current consumption with register settings
optimized for sensitivity.
14.7
mA
Receive mode, 1.2 kBaud, register settings optimized for
reduced current, input well above sensitivity limit.
See Figure 3 for current consumption with register settings
optimized for sensitivity.
15.6
mA
Receive mode, 38.4 kBaud, register settings optimized for
reduced current, input at sensitivity limit.
See Figure 3 for current consumption with register settings
optimized for sensitivity.
14.6
mA
Receive mode, 38.4 kBaud, register settings optimized for
reduced current, input well above sensitivity limit.
See Figure 3 for current consumption with register settings
optimized for sensitivity.
16.9
mA
Receive mode, 250 kBaud, register settings optimized for
reduced current, input at sensitivity limit.
See Figure 3 for current consumption with register settings
optimized for sensitivity.
15.6
mA
Receive mode, 250 kBaud, register settings optimized for
reduced current, input well above sensitivity limit.
See Figure 3 for current consumption with register settings
optimized for sensitivity.
34.2
mA
Transmit mode, +12 dBm output power, 868 MHz
30.0
mA
Transmit mode, +10 dBm output power, 868 MHz
16.8
mA
Transmit mode, 0 dBm output power, 868 MHz
16.4
mA
Transmit mode, 6 dBm output power, 868 MHz.
33.4
mA
Transmit mode, +11 dBm output power, 915 MHz
30.7
mA
Transmit mode, +10 dBm output power, 915 MHz
17.2
mA
Transmit mode, 0 dBm output power, 915 MHz
17.0
mA
Transmit mode, 6 dBm output power, 915 MHz

Table of Contents

Other manuals for Texas Instruments CC1101

Related product manuals