Table 4: Current Consumption
Parameter
Min
Typ
Max
Unit
Condition
Current consumption,
433 MHz
16.0
mA
Receive mode, 1.2 kBaud, register settings optimized for reduced
current, input at sensitivity limit
15.0
mA
Receive mode, 1.2 kBaud, register settings optimized for reduced
current, input well above sensitivity limit
15.7
mA
Receive mode, 38.4 kBaud, register settings optimized for
reduced current, input at sensitivity limit
15.0
mA
Receive mode, 38.4 kBaud, register settings optimized for
reduced current, input well above sensitivity limit
17.1
mA
Receive mode, 250 kBaud, register settings optimized for
reduced current, input at sensitivity limit
15.7
mA
Receive mode, 250 kBaud, register settings optimized for
reduced current, input well above sensitivity limit
29.2
mA
Transmit mode, +10 dBm output power
16.0
mA
Transmit mode, 0 dBm output power
13.1
mA
Transmit mode, 6 dBm output power
Current consumption,
868/915 MHz
15.7
mA
Receive mode, 1.2 kBaud, register settings optimized for
reduced current, input at sensitivity limit.
See Figure 3 for current consumption with register settings
optimized for sensitivity.
14.7
mA
Receive mode, 1.2 kBaud, register settings optimized for
reduced current, input well above sensitivity limit.
See Figure 3 for current consumption with register settings
optimized for sensitivity.
15.6
mA
Receive mode, 38.4 kBaud, register settings optimized for
reduced current, input at sensitivity limit.
See Figure 3 for current consumption with register settings
optimized for sensitivity.
14.6
mA
Receive mode, 38.4 kBaud, register settings optimized for
reduced current, input well above sensitivity limit.
See Figure 3 for current consumption with register settings
optimized for sensitivity.
16.9
mA
Receive mode, 250 kBaud, register settings optimized for
reduced current, input at sensitivity limit.
See Figure 3 for current consumption with register settings
optimized for sensitivity.
15.6
mA
Receive mode, 250 kBaud, register settings optimized for
reduced current, input well above sensitivity limit.
See Figure 3 for current consumption with register settings
optimized for sensitivity.
34.2
mA
Transmit mode, +12 dBm output power, 868 MHz
30.0
mA
Transmit mode, +10 dBm output power, 868 MHz
16.8
mA
Transmit mode, 0 dBm output power, 868 MHz
16.4
mA
Transmit mode, 6 dBm output power, 868 MHz.
33.4
mA
Transmit mode, +11 dBm output power, 915 MHz
30.7
mA
Transmit mode, +10 dBm output power, 915 MHz
17.2
mA
Transmit mode, 0 dBm output power, 915 MHz
17.0
mA
Transmit mode, 6 dBm output power, 915 MHz

Table of Contents

Other manuals for Texas Instruments CC1101

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Texas Instruments CC1101 and is the answer not in the manual?

Texas Instruments CC1101 Specifications

General IconGeneral
BrandTexas Instruments
ModelCC1101
CategoryTransceiver
LanguageEnglish

Related product manuals