7.23.2 TRNG Switching Characteristics
over operating free-air temperature range (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
TRNGCLK
F
TRNG input clock frequency 9.5 10 25 MHz
TRNG
STARTUP
TRNG startup time 100 µs
TRNG
LAT32
Latency to generate 32 random bits
Decimation ratio = 4, TRNG clock =
20MHz
6.4 µs
TRNG
LAT256
Latency to generate 256 random bits
Decimation ratio = 4, TRNG clock =
20MHz
51.2 µs
7.24 Emulation and Debug
7.24.1 SWD Timing
over operating free-air temperature range (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
f
SWD
SWD frequency 10 MHz
www.ti.com
MSPM0G3507, MSPM0G3506, MSPM0G3505
SLASEX6A – FEBRUARY 2023 – REVISED JUNE 2023
Copyright © 2023 Texas Instruments Incorporated
Submit Document Feedback
51
Product Folder Links: MSPM0G3507 MSPM0G3506 MSPM0G3505