Programming the Control Panel Premier 412/816/832 Installation Manual
48 INS159-13
 Walk Test
This output type activates when the user selects the Zone Test
option (menu 90).
 Confirmed Alarm
This output type activates when two different zones are violated
from any armed partition.
 ARC 2 Active
This output type activates when the panel is communicating to
ARC2.
 Zone Locked-Out
This output type activates when the one or more zones are locked
out after the confirmation timer has expired.
 AC Fail
This output type activates when the mains supply is disconnected.
 Battery Fault
This output type activates when the system detects a fault from the
stand-by battery.
 Poll Timer
This output is linked to the Global System Timer 14 "Poll IP Every" in
minutes. Thus if this timer is programmed with a non-zero value,
when the timer times out, this new output "Poll Timer" will activate
for 10 seconds and then reset. This cycle will repeat every time the
"Poll IP Every" timer expires.
Group - Partition Output Types
This group contains the partition output types as listed below:
 PA Alarm
This output type activates when a PA alarm is generated in the
selected Partition. If another PA alarm is generated the output will
reset for 3 seconds then reactivate.
 Duress Alarm
This output type activates when a Duress alarm is generated in the
selected Partition. If another Duress alarm is generated the output
will reset for 3 seconds then reactivate.
 Burglar Alarm
This output type activates when a Burglar alarm is generated in the
selected Partition. If another Burglar alarm is generated the output
will reset for 3 seconds then reactivate.
 Medical Alarm
This output type activates when a Medical alarm is generated in the
selected Partition. If another Medical alarm is generated the output
will reset for 3 seconds then reactivate.
 24Hr - Water Alarm
This output type activates when a 24hr Water alarm is generated in
the selected Partition. If another 24hr Water alarm is generated the
output will reset for 3 seconds then reactivate.
 24Hr - Gas Alarm
This output type activates when a 24hr Gas alarm is generated in
the selected Partition. If another 24hr Gas alarm is generated the
output will reset for 3 seconds then reactivate.
 24Hr - Low Temp Alarm
This output type activates when a 24hr Low Temperature alarm is
generated in the selected Partition. If another 24hr Low Temperature
alarm is generated the output will reset for 3 seconds then
reactivate.
 24Hr - High Temp Alarm
This output type activates when a 24hr High Temperature alarm is
generated in the selected Partition. If another 24hr High
Temperature alarm is generated the output will reset for 3 seconds
then reactivate.
 Tamper
This output type activates when a Tamper alarm is generated in the
selected Partition. If another Tamper alarm is generated the output
will reset for 3 seconds then reactivate.
 Trouble
This output type activates when a Trouble alarm is generated in the
selected Partition. If another Trouble alarm is generated the output
will reset for 3 seconds then reactivate.
 Fire
This output type activates when a Fire alarm is generated in the
selected Partition. If another Fire alarm is generated the output will
reset for 3 seconds then reactivate.
 Trouble/Tamper
This output type activates when a Trouble or Tamper alarm is
generated in the selected Partition.
 Bell
This output type activates when an alarm is generated in the
selected Partition.
 Strobe
This output type activates when an alarm is generated in the
selected Partition.
 Entry
This output type activates when the selected Partition is in entry
mode.
 Exit
This output type activates when the selected Partition is in exit
mode.
 Armed
This output type activates when the selected Partition is stay or
away armed.
 Stay Armed
This output type activates when the selected Partition is stay armed.
 Ready
This output type activates when the selected Partition is ready for
arming.
 Bypass
This output type activates when the selected Partition has one or
more zones bypassed.
 Sensor Reset on Exit
This output type is normally active and deactivates for 2 seconds
when the selected Partition is in exit mode.
 Sensor Reset on Reset
This output type is normally active and deactivates for 2 seconds
when the user resets the selected Partition.
 Single Pulse on Arming
This output type activates for 2 seconds when the selected Partition
is armed.