Premier 412/816/832 Installation Manual Quick Reference Guide
INS159-13 83
Programming System Outputs
System Output Types
00 Courtesy
01 Successful Transmission
02 Log 80% Full
03 Program Mode Selected
04 Download In Progress
05 Timed Arming Countdown
06 Zone Soak Test Active
07 Zone Soak Test Failed
08 Latched AC Fail
09 Telephone Line Fault
10 Smoke Alarm
11 Box/Auxiliary Tamper
12 Date Time Loss
13 Zone Trouble/Tamper
14 Keypad Tamper/Removed
15 Service Fault
16 Output 1 Fault
17 Output 2 Fault
Partition Output Types
00 PA Alarm
01 Duress Alarm
02 Burglar Alarm
03 Medical Alarm
04 24Hr - Water Alarm
05 24Hr - Gas Alarm
06 24Hr - Low Temp Alarm
07 24Hr - High Temp Alarm
08 Tamper
09 Trouble
10 Fire
11 Fire Fault
12 Bell
13 Strobe
14 Entry
15 Exit
16 Armed
17 Stay Armed
18 Ready
Zone Output Types
01 - 32 Zone Mimic 01 - 32
Output Attributes
1 Partition 1
2 Partition 2
3 Partition 3
4 Partition 4
18 Siren/Bell Fault
19 Smoke Sensor Fault
20 Auxiliary Fuse Fault
21 Latched Battery Fault
22 Service Required/Test Fail
23 Fail To Communicate
24 Control Timer 1 Active
25 Control Timer 2 Active
26 Control Timer 3 Active
27 Control Timer 4 Active
28 PC Output 1
29 PC Output 2
30 Walk Test
31 Confirmed Alarm
32 ARC 2 Active
33 Zones Locked Out
34 AC Fail
35 Battery Fault
36 Poll Timer
19 Bypass
20 Sensor Reset on Exit
21 Sensor Reset on Reset
22 Single Pulse on Arming
23 Double Pulse on Arming
24 Chime
25 Door Strike
26 Cross Zone Time Active
27 Single Pulse on Disarming
28 Reset Required
29 Acknowledgement Required
30 Confirmed Alarm
31 Alarm Abort
32 Away Armed
33 Away Armed/Exit
34 Detector Latch
35 Armed/Alarm
36 Arm Failed
37 All Armed
33 - 64 Zone Alarm 01 - 32
5 User Test
6 Inverted
7 Latching
8 Pulsed
Programming The Communicator
Enable On-Board Communicator
Enable DTMF Dialling
Switch to Pulse Dialling after 3
rd
Attempt
Enable European Pulse Dialling
Enable Auto Test Transmission
Enable Cancel Call Waiting
Enable Backup to Alarm Receiving Centre
Enable Blind Dialling
Primary and secondary telephone numbers
Account Numbers (partitions 1-4)
Protocol Type:
Disabled
Pulse Format
Express Format
Fast Format/Speech Module
Contact ID
SIA Level 2/3
Pager
Mobile Phone
Dial Attempts
Partition Options:
Report for Partition 1
Report for Partition 2
Report for Partition 3
Report for Partition 4
Reporting Options:
Priority Alarm and Cancel Events
Alarm and Cancel Events
Open and Close Events
Bypass and Unbypass Events
Maintenance Alarm Events
Tamper Alarm Events
Test Transmission Events
Restore Events
Pulse Format Options:
Use 1900Hz Carrier
Use 40 PPS Baud Rate
Enable Parity
Use 2 Digit Events
Use 2300Hz Handshake
Use 2300Hz Kiss-Off
Use Fast/Slow Format
Fast Format/Speech Reporting Channels
Report Channel 1
Report Channel 2
Report Channel 3
Report Channel 4
Report Channel 5
Report Channel 6
Report Channel 7
Report Channel 8
Protocol Options:
Disable SIA Modifier Blocks/Enable Speech Module
Disable Events for Each Partition
Pager Terminator = * (Star)
Send Pager Terminator Twice/Send SIA Text
Pager DTMF Tones = 500mS
Disable Zone Restorals
Communication Acknowledgement Tone
Connect via IP