Service Faults Displayed on LED Keypads
General Warnings
Press to view type, lights 1 - 5 indicate:
1 = AC Fail
2 = Arming Fob has Low Battery
3 = Soak Test Active
Box Tamper & Auxiliary Input:
Press to view type, lights 1 - 5 indicate:
1 = Box Tamper 4 = Auxiliary Tamper
2 = Auxiliary Tamper 5 = Bell Tamper
3 = Auxiliary PA 6 = RadioPlus Tamper
7 = Low Fob Battery detected
Zone Tamper/Trouble
Press to view zone number
Keypad Tamper/Removed
Press to view keypad number
Equipment Faults
Press to view fault type, lights 1 - 8 indicate:
1 = Output 1 Fault
2 = Output 2 Fault
3 = Siren/Bell Fault
4 = 2-Wire Smoke Sensor Fault
5 = Auxiliary Fuse Failed
6 = Battery Fault
7 = Service Timer/Zone Soak Test Failed
8 = Com1 Fault or Fail To Communicate
Service Faults Displayed on LCD Keypads
Auxiliary Tamper (Aux Input)
Auxiliary Tamper (UK Bell Module)
Bell Tamper (UK Bell Module)
2-Wire Smoke Sensor Fault
Service Timer/Zone Soak Test Failed
Com1 Fault or Fail To Communicate
Enter User Code ???? followed by
View/Acknowledge Service Faults
View Event Log (LCD Only)
Select User Programming Mode