FAQ (How to check the power/booting failure/rebooting)
Symptoms Diagnosis and troubleshooting plans
How to check
power/booting
failures/rebooting
Check if the hardwiring cable is wrongly wired or if the terminal is defective.
Replace the main body of dash cam. If the power is on properly, then you can see that the product was defective.
If there is no power after replacing the dash cam, then suspect there is something wrong with the wiring.
- Check if the GND connection is ok.
Check if the SD card is defective.
Insert a normal SD card and ensure everything is ok.
- A defective SD card can cause booting failures or rebooting.
Check the B+ wirings.
Check the fuse connected to B+. After some time, check if the dash cam is terminated.
- Each car has its own characteristics. If the indoor lamp is B+, after some time, it can be accidentally turned off.
※ If you have a power supply, connect it to your product to perform tests. You can see if the product or the cable is
defective.
Check the power jack.
If the power jack is not correctly connected and has poor contact, it can cause repeated rebooting and the problem can
be recognized as a power failure.