ARE – Door switch Strip circuits
Thor Kitchen internal use only
• CN5 pin2 Green wire will supply +5Vdc to the CM terminal of the door
switch. When door is closed 5vdc will pass thru door switch terminal CM
to NO and exit the Black wire returning to CN5 pin 1 on PCB. As long and
5Vdc is sensed by PCB at CN5 pin1 control will know the door is closed and
no power will be sent to oven cavity light.
• When the oven door is opened, and door switch plunger extends. Switch
contact CM to NO will be opened stopping the 5Vdc going to CN5 pin 1.
When ERC senses the voltage loss control will close light relay sending
voltage of 120V out CN4 pin3 Brown wire to cavity light socket terminal
(2). Voltage will pass thru Cavity lamp socket and exit Terminal (N) to
white Neutral wire traveling back to terminal block completing the circuit.