ARE – Manual light switch
Thor Kitchen internal use only
• CN2 pin3 Blue wire will supply +5Vdc to the NO terminal of the control panel light
switch. When control panel switch is Turned to ON position(ARE36) or pushed
(ARE30) 5vdc will pass thru switch terminal NO to CM and exit the Blue wire
returning to CN2 pin 1 on PCB. When ERC senses the voltage input of 5vdc in
CN2 pin1 control will close light relay sending voltage of 120V out CN4 pin3 Brown
wire to cavity light socket terminal (2). Voltage will pass thru Cavity lamp socket
and exit Terminal (N) to white Neutral wire traveling back to terminal block
completing the circuit.
• When control panel switch is in OFF position contacts CM to NO will be open
stopping the 5Vdc going to CN2 pin 1. When ERC senses there is no voltage input
on CN2 pin 1 cavity light relay is turned off.