Thor Kitchen internal use only
Troubleshooting E00
E00 error code
E00
Control reading
sensor as open
or shorted
Check both PCB and harness
terminals for corrosion,
Clean terminals check for a
tight fit between connectors.
Unplug and reseat connector.
Retest did error code return
Replace PCB
If Sensor
reads open
or shorted
Replace
sensor
Remove control panel and
locate the NTC Plug
connector. Verify connector
is plugged in. Removed NTC
connector and check
resistances between the two
wire. At room temp is
sensor around 1.5MΩ
NO
YES
YES