Component check
Thor Kitchen internal use only
Before testing or condemning a component preform the
following checks:
Note:
1. The most common cause for control failure is corrosion on connectors ( high resistances).
Disconnecting and reconnecting wire connectors will be necessary through the testing
process.
2. Any issues arising in the first few days of use should be checked for mis-wiring or loose
terminal connections prior to condemning a control board .
1. All test and checks should be made with Digital voltmeter having a sensitivity of 20,000
ohms per-volt DC or greater.
2. Check all terminal connections and crimps, Looking for loose or broken wires, failed
terminals or wires not full inserted or crimped prior to condemning any component on
this range.
3. Resistances checks must be made with power cord unplugged from the power
sources, and wiring harness or connector disconnected from the component prior to
testing.
Note: All test values stated below are at room temperature of (77°F / 25°C)
Normal : 16 Ω +/- 5
Abnormal : or OL