Figure44
1.Sprayer-pressurecontrol5.Spraywand
2.Agitation-pumplever
6.Sprayer-pressuregauge
3.Narrow-spraypatternlever
7.Sprayer-pump/tank-agitation
switch
4.Wide-spraypatternlever
8.Sprayer-wand-pressure
control
9.MovethethrottletotheFASTposition.
10.Pullrearwardonthetank-agitationlevertotheON
position.
Note:Thewaterinthetankwillcirculate.
11.Addthespeciedamountofchemicalconcentrateto
thetankasdirectedbythechemicalmanufacturer.
Important:Ifyouareusingawettable-powder
chemical,mixthepowderwithasmallamountof
watertoformaliquidslurrybeforeaddingthe
chemicalmixturetothetank.
12.Addremainingwatertothetankandinstallcaponto
thellerneckofthetank.
Note:Allowthecontentofthesprayertanktomix
thoroughly.
EmptyingtheSprayerTank
Operatorsuppliedequipment:Drainhosewitha1/2–14
inchNPTmalecouplingandadraincontainer(capacityvaries
withremainingsprayertankcontent).
1.Movethemachinetoalevelsurfaceatthedesignated
areaforemptyingandcleaningthesprayertank,move
motion-controllevertotheNEUTRALposition,shut
offtheengine,andsettheparkingbrake.
2.Removetheplugfromthedrainvalveforthesprayer
tank(Figure45).
Note:Thedrainvalveislocatedattheleftsideofthe
machine.
Figure45
1.Drainvalve2.Plug
3.Threadadrainhose(operatorprovided)intotheend
ofthedrainvalve.
4.Putthefreeendofthedrainhoseintoacontainerwith
enoughcapacitytoholdtheremainingcontentofthe
sprayertank.
Note:Usethequantitymarksatthefront,leftsideof
thesprayertankfordeterminethequantityofchemical
solutioninthetank.
5.Rotatethehandleforthedrainvalveclockwise90°to
drainthetank(Figure45).
Note:Allowthesprayertanktodraincompletely.
6.Closethetank-drainvalve,removethedrainhoseand
installthedrainplugintothevalve(Figure45).
Note:Disposeofthesprayerchemicalsaccording
tolocalcodesandthechemicalmanufacturer's
instructions.
CleaningtheSprayerTank
ServiceInterval:Aftereachuse
WARNING
Swallowingorinhalingchemicalscouldcause
seriousinjuryordeath.
•Donotcleansprayernozzlesusingyourmouth
orblowingthroughthenozzles.
•Replaceallwornanddamagedsprayernozzles.
•Ensurethatthenozzlesareinstalledcorrectly.
Important:Alwaysemptyandcleanthesprayer
immediatelyaftereachuse.Failuretodosomaycause
40