10. Allo w all of the w ater in the tank to spra y out
though the nozzles .
11. Chec k the nozzles to ensure that they are all
spra ying cor rectly .
12. Set the master boom switc h to the Off
position, set the pump switc h to the Off
position, and stop the engine .
13. R e peat ste ps 4 through 12 at least 2 more times
to ensure that the spra y system is fully cleaned.
On the last cycle , r un the last few g allons of
w ater through the drain v alv e to clear the drain
tubing .
14. Clean the strainer; refer to Cleaning the Suction
Strainer in Cleaning , pag e 59 .
Important: If y ou used w etta ble po w der
chemicals, clean the strainer after each
tank.
15. Using a g arden hose , spra y off the outside of
the spra yer with clean w ater .
16. R emo v e the nozzles and clean them b y hand.
R e place damag ed or w or n nozzles .
32