Ignition Switch T esting
g353109
Figure 142
Using a digital multimeter set to the OHM or Continuity setting, verify the
following:
Position
Circuit Continuity
OFF
None
RUN B+R+I+A
ST AR T B+R+I+S
Hourmeter Replacement
Hourmeter Removal
1. Connect the battery by installing the positive cable rst, then the negative
cable to the battery .
2. Disconnect the battery by removing the negative cable rst, then the positive
cable from the battery .
3. Remove the control panel. Refer to Control Panel Removal ( page 8– 9 ) .
4. Compress the 2 tabs on the side of the switch and remove the hourmeter .
Hourmeter Installation
1. Insert the hourmeter into the control panel.
2. Install the control panel. Refer to Control Panel Installation ( page 8– 12 ) .
3. Connect the battery by installing the positive cable rst, then the negative
cable to the battery .
Hourmeter T esting
With the ignition switch in the RUN position and the PT O switch closed (ON),
verify battery voltage and ground to the hourmeter .
Electrical: Service and Repairs Page 8–18 2000 Series Z MASTER®Service Manual