Trunks
300 Trunk Assignment
Strata CTX Programming - Part 2: CTX WinAdmin Programming 11/03 6-9
Trunks
308 Trunk Timer
Prerequisite Program: 300 page 6-6
These commands assign Trunk timers.
1. Complete the “Trunk Timer/DIT
Record Sheet” on page D-27.
2. From the Program Menu, click
Trunk > Assignment, then click the
Timer tab. The Trunk Timer and
DIT Assignments screen displays
(shown right).
3. Enter Trunk equipment number
field. Enter Program 308 data.
•List to view a summary list of
programmed Trunks timers.
Copy – to copy to trunk timer
ports.
4. Click Submit.
FIELD DESCRIPTION
Trunk Number Enter the Trunk Number.
Possible values: 1~64 (CTX100), 1~96 (CTX670 Basic),
1~264 (CTX670 Exp.), (default = no value)
01 Signaling Method Specify the format for the interface being used.
Possible values: Nothing (default), ANI/DNIS-MCI, ANI/DNIS-Sprint or CLASS
(Caller ID)
02 Signaling Contents Specify the contents of the ANI/DNIS format.
Possible values: ANI and DNIS, ANI only, DNIS only or DID only (default = no
value).
03 CLASS Equipment No. If the CLASS type is chosen, the trunk must be assigned to a Caller ID circuit. Enter
the RCIU/RCIS equipment number as xxyyzz.
Possible values: xx = Cabinet 01(CTX100); 01~02 (CTX670 Basic); 01~07
(CTX670 Exp.)
yy = Slot 01~08 (CTX100); 01~10 (CTX670)
zz = Circuit 01~08
Notes
CLASS equipment numbers are required when assigning a trunk to a RCIU/
RCIS circuit.
It can also be used to display the equipment location of existing caller ID circuit
to trunk assignments. Example: If the trunk should be connected to a caller ID
circuit (RCIU/RCIS) in cabinet shelf 5, slot 2, circuit 3, enter 050203.