Trunks
315 T1 Trunk Card
6-20 Strata CTX Programming - Part 2: CTX WinAdmin Programming 11/03
315 T1 Trunk Card
Prerequisite Program: 100 page 4-1
This command assigns T1 Trunk Card Data to the system.
1. Complete the “Trunk Timer/DIT
Record Sheet” on page D-27.
2. From the Program Menu, click
Trunk > T1. The T1 Trunk Card
Data Assignment screen displays
(shown right).
3. Enter T1 card location in Shelf/Slot
field (xxyy). The selected slot
requires a DTU Card.
xx = Cabinet 01~07
yy = Slot 01~10
...or click the following buttons:
•List to view a summary list of programmed Trunks.
Copy – to T1 trunk equipment.
4. Enter values for Program 315.
5. Click Submit.
01 Day1 Destination Type
02 Day2 Destination Type
03 Night Destination Type
Select Destination Type for each.
Possible values: None (default), Dialing Digits or Night Bell
Day1 Destination
Day2 Destination
Night Destination
Enter Destination for each.
Possible values: Up to 32 ASCII characters (default = no value)
To intercept with a DN use 0~99999
To intercept with a Network DN use 1~32
To intercept with Dial Digits Paging 1~16
FIELD DESCRIPTION
T1 Equipment
Location
Enter the RDTU PCB equipment location.
Possible values: xx = cabinet 01; yy =slot 03, 05, or 07
...or xx = cabinet 02~07; yy =slot 01, 03, or 05
Cabinet – Select 01 for Base and Expansion cabinet (CTX100).
Select 01 for Base and 02~07 respectively for each Expansion
cabinet (CTX670).
Slot – Select 01~04 for Base slots and 05~08 for Expansion slots
(CTX100).
Select 01~08 for Base slots and 01~10 for Expansion slots
(CTX670)
(default = no value)
01 Coding Format Select the Coding Format.
Possible values: None, PZC, B8ZS (default) or ZCS
FIELD DESCRIPTION