CE50 Image control related
service call
Temperature/humidity sensor abnormality: The
output value of this sensor is out of a specified
range.
P. 6-98
CE60 Drum thermistor-Y abnormality: The output value of
the drum thermistor-Y is out of a specified range.
P. 6-98
CE70 Drum drive switching abnormality: The drum
switching detection sensor (S19) is not turned ON
after the drum motor was rotated for a specified
period of time.
P. 6-99
CE71 Drum phase adjustment abnormality: Drum phase
sensors (Color drum phase sensor (S43) and K
drum phase sensor (S44)) are not turned ON after
the drum motor was rotated for a specified period of
time.
P. 6-100
CE90 Drum thermistor-K abnormality: The output value of
the drum thermistor-K is out of a specified range.
P. 6-98
CEC0 Copy process related
service call
2nd transfer roller position detection abnormality:
The 2nd transfer roller does not contact/release
normally.
P. 6-104
CF10 Finisher related
service call
Communication module SRAM reading failure.
[MJ-1101]
P. 6-87
CF90 Laser optical unit
related service call
Laser optical unit shutter abnormality. P. 6-70
F070 Communication
related service call
Communication error between System-CPU and
Engine-CPU
P. 6-64
F090 Circuit related service
call
SRAM abnormality on the SYS board P. 6-66
F100 Other service call HDD format error: HDD cannot be initialized
normally.
P. 6-105
F101 HDD unmounted: Connection of HDD cannot be
detected.
P. 6-105
F102 HDD start error: HDD cannot become ‘Ready’ state. P. 6-105
F103 HDD transfer time-out: Reading/writing cannot be
performed in the specified period of time.
P. 6-105
F104 HDD data error: Abnormality is detected in the data
of HDD.
P. 6-105
F105 HDD other error P. 6-105
F106 Point and Print partition damage P. 6-105
F107 /BOX partition damage P. 6-105
F108 /SHA partition damage P. 6-105
F110 Communication
related service call
Communication error between System-CPU and
Scanner-CPU
P. 6-64
F111 Scanner response abnormality P. 6-64
F120 Other service call Database abnormality: Database is not operating
normally.
P. 6-105
F130 Invalid MAC address P. 6-106
F140 Accelerator ASIC format error P. 6-106
F200 Data Overwrite option (GP-1070) disabled P. 6-106
F350 Circuit related service
call
SLG board abnormality P. 6-67
F400 Circuit related service
call
SYS board cooling fan abnormality P. 6-106
Error code Classification Contents Troubleshooting

Table of Contents

Other manuals for Toshiba e-studio2330c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba e-studio2330c and is the answer not in the manual?

Toshiba e-studio2330c Specifications

General IconGeneral
BrandToshiba
Modele-studio2330c
CategoryAll in One Printer
LanguageEnglish

Related product manuals