144 GX9 ASD Installation and Operation Manual
Number of PG Input Pulses
Program Feedback PG Settings
This parameter is used to set the number of pulses output from a shaft-mounted
encoder that is used to indicate one revolution of rotation (360°) of the motor or
of the motor-driven equipment.
Note: The PG Vector Feedback Board option is required to use this
feature.
Direct Access Number — F367
Parameter Type — Numerical
Factory Default 500
Changeable During Run — No
Minimum — 1
Maximum — 9999
Selection of Number of PG Input Phases
Program Feedback PG Settings
This parameter determines the type of information that is supplied by the phase
encoder.
Note: The PG Vector Feedback Board option is required to use this
feature.
Settings:
1 — Single Phase
2 — Two Phase
Direct Access Number — F368
Parameter Type — Selection List
Factory Default Two Phase
Changeable During Run — No
PG Disconnection Detection
Program Feedback PG Settings
This parameter Enables/Disables the system’s monitoring of the PG connection
status when using encoders with line driver outputs.
Note: The PG Vector Feedback Board option is required to use this
feature.
Settings:
0 — Disabled
1 — Enabled
Direct Access Number — F369
Parameter Type — Selection List
Factory Default Disabled
Changeable During Run — Yes
Electronic Gear Setting (Pulses/Rotations)
Program Feedback PG Settings
This parameter sets the number of pulses per revolution when using a shaft-
mounted encoder and the PG Option Board for closed loop speed control.
Direct Access Number — F370
Parameter Type — Numerical
Factory Default 1000
Changeable During Run — Yes
Minimum — 100
Maximum — 4000