4. Turn the LCD module face down and remove the screw (E) fixing the board. Then
open the bent portion of the TCP of the board and remove the backlight.
Screw loosening torque: 1.2kg.cm
(
E
)
Figure 4-68 Replacing Sharp fluorescent lamp (XGA) (4)
Do not hold the edge.
Do not hold the edge.
Figure 4-69 Replacing Sharp fluorescent lamp (XGA) (5)
TECRA S3 Maintenance Manual (960-532) [CONFIDENTIAL] 4-88