2. Install the metal fitting A (K), metal fitting B (L) and lump cover (J) on the backlight
unit and secure the two screws (I).
An order of installing is: (K), (L), and (J).
(
J
)
(
K
)
(
L
)
(
I
)
(
I
)
Screw tightening torque: 1.0kgcm
Figure 4-77 Replacing Sharp fluorescent lamp (XGA) (13)
3. Install the light guide plate (O) on the backlight unit. (Insert the thick side of the light
guiding plate in the lamp unit.)
(O)
Insert the light guide straight not to
deform the reflector.
Lump unit side
Figure 4-78 Replacing Sharp fluorescent lamp (XGA) (14)
TECRA S3 Maintenance Manual (960-532) [CONFIDENTIAL] 4-96