E6581595
D-8
4
Reset parameters to default settings 
Use the  parameter to reset all parameters back to their default settings. To use this function, set parameter
= or .
Refer to section 4.3.2 for details.
Call saved customer settings 
Customer settings can be batch-saved and batch-called.
These settings can be used as customer-exclusive default settings.
To use this function, set parameter = or .
Refer to section 4.3.2 for details.
Search changed parameters 
Automatically searches for only those parameters that are programmed with values different from the standard
default setting. To use this function, select the  parameter.
Refer to section 4.3.1 for details.
4.3.1 Searching for and resetting changed parameters
 : Automatic edit function
Note 1: If you reset a parameter to its factory default, the parameter will no longer appear in .
Note 2: It may take several seconds to display changed parameters because all data stored in the user parameter
group  is checked against the factory default settings. To cancel a parameter search, press the MODE
key.
Note 3: Parameters which cannot be reset to the default setting after setting  to are not displayed.
Refer to section 4.3.2 for details.
• Function
Automatically searches for only those parameters that are programmed with values different from the standard
default setting and displays them in the . Parameter setting can also be changed within this group.

Table of Contents

Other manuals for Toshiba TOSVERT VF-nC3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-nC3 and is the answer not in the manual?

Toshiba TOSVERT VF-nC3 Specifications

General IconGeneral
ModelVF-nC3
CategoryInverter
Output Frequency Range0.1 to 400 Hz
Control MethodV/f control, sensorless vector control
Overload Capacity150% for 60 seconds
Input Frequency50/60 Hz
Enclosure RatingIP20
Input Voltage200-240V AC
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheat, Short Circuit
Ambient Temperature-10°C to +50°C
CommunicationModbus RTU
Cooling MethodFan Cooled
Operating Temperature-10°C to +50°C
Storage Temperature-20°C to +60°C
Humidity5 to 95% RH (non-condensing)
AltitudeUp to 1000m
Braking UnitBuilt-in braking transistor (for models up to 22kW), External braking resistor required

Related product manuals