n Output data – TBEN-S1-8DXP [}53]
control word + 5 words
Word no. Bit no.
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Control
0x0000
OUT
- - - - - - - - - - - - - - - -
0x0001 - - - - - - - - DX7
C7P4
DX6
C6P4
DX5
C5P4
DX4
C4P4
DX3
C3P4
DX2
C2P4
DX1
C1P4
DX0
C0P4
Latch
reset
0x0002 - - - - - - - - DX7 DX6 DX5 DX4 DX3 DX2 DX1 DX0
CNT
reset
0x0003 - - - - - - - - - - - - - - - CNT
reset
PWM Ch3
0x0004 - - - - - - - - Duty Cycle
PWM Ch7
0x0005 - - - - - - - - Duty Cycle