Bit Designation Meaning Default value
5 Manual setting
requires reset
0 = interface can activate changes to link paramet-
ers (auto-negotiate, duplex mode, interface speed)
automatically
1 = device requires a Reset service to be issued to
its Identity Object in order to adapt the changes.
0
6 Local Hardware
Fault
0 = interface detects no local hardware fault
1 = local hardware error detected
0
Common services
Service code Class Instance Meaning
Dec. Hex.
1 0x01 yes yes Get_Attribute_All
14 0x0E yes yes Get_Attribute_Single
76 0x4C No yes Enetlink_Get_and_Clear