EasyManua.ls Logo

Universal Robots UR5e - Screwdriving Setup

Universal Robots UR5e
364 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuring the
Screwdriver
Interface
1. Use the Interface drop-down menu at the top of the screen to
change the displayed content based on signal type.
2. Under Input, configure the signals that the robot receives from the
screwdriver:
OK: High when tightening ends successfully, if not selected
this condition is not available in the Screwdriving program
node
Not OK: High when tightening ends with errors, if not selected
this condition is not available in the Screwdriving program
node
Ready: High when the screwdriver is ready to be started, if not
selected this condition is not checked
3. Under Output configure the signals that the robot sends to the
screwdriver:
Start: starts the tool tightening or loosening a screw depending
only on wiring.
Program Selection: one integer, or up to four binary signals,
can be selected to activate different tightening configurations
stored in the screwdriver
Program Selection Delay: wait time to be used after changing
the screwdriver’s program to make sure it is active
Typical Orientation
values
Values (in Rotation Vector [rad] notation) are illustrated in the following
table.
Screwdriving axis parallel to
the negative Y direction of the
robot’s tool flange1
Orientation
RX: 1.5708
rad
RY: 0.0000
rad
RZ: 0.0000
rad
User Manual 296 UR5e