Programming and calibrating
49
4. Hold down the key for approx. 2 seconds:
5. Press / to change the displayed correction value by the measured
deviation.
6. Briefly press to exit the programming mode.
Use the key to exit the temperature calibration.
7.3 Programming heating and agitating
7.3.1 Overview
The heater installed in the Milk Shuttle heats the feed in the container to the
required temperature (target temperature). The heater switches off as soon as the
target temperature is reached. Due to the inertia of thermal systems, the actual
temperature will temporarily exceed the target temperature.
The agitator ensures an even temperature distribution in the feed. The operating
and break times of the agitator should be adapted to the type of feed that is used.
The following table shows field-proven values:
Slow mode
(Level I)
Fast mode
(Level II)
Operating time Break time
Calf milk replacer
(CMR)
3 s 4 min
10 s 1:30 min
Whole milk
10 s 1:30 min
Information
If residues develop along the bottom of the container:
• increase the operating time, and/or
• shorten the break time
Information
In this chapter you will use the programming mode.
You can recognize this programming mode in that the values to be programmed
(the warning temperature here), are set in angle brackets:
SET Temperature
14.5 C >+0.0<
-
Temp. Warning level
max > 45.0 C<