Programming and calibrating
55
3. Press (approx. 1 second) to switch to the
programming mode:
4. Press / to set the required duration
of the cleaning program (here: 4 minutes):
5. Briefly press the key and use
the / keys to set the required temperature:
6. Briefly press the key.
7. This assigns the preselection key a cleaning time of 4 minutes and ends
the programming mode.
In the following example, the preselection key is programmed for a cleaning
time of 5 minutes and the extended cleaning incl. heating. Please note that
heating only works during mains operation.
1. Hold down the key for approx. 2 seconds.
2. Briefly press the key:
3. Press (approx. 2 seconds) to switch to the
programming mode:
4. Use / to set the required cleaning duration (4 min.):
5. Briefly press the key:
6. Press / to select the heating temperature:
7. Confirm the entry by briefly pressing the key.
SET Cleaning
1:>02:00< ---.- C
-
SET Cleaning
1:>04:00< ---.- C
SET Cleaning
1: 04:00 >---.- C<
Cleaning 40.0 C
3: 05:00 25.3 C
SET Cleaning
3:>05:00< 40.0 C
SET Cleaning
3: 04:00 > 40.0 C<
-
SET Cleaning
3: 04:00 > 42.0 C<