43
7 OPERATING INSTRUCTIONS
7.1 LAYOUT OF THE MCU
Operation of the Oilcon
®
Oil Discharge Monitoring and Control System is controlled and recorded by
the MCU.
A representation of the control panel of the MCU, as fitted in the Cargo Control Room, is shown
below.
Figure 32: MCU layout
The MCU control panel contains the following:
Control key switch
USB connector
RS-232 serial communication port
Reset button
Touch screen panel
7.1.1 Control key switch
The control key switch is used to put the MCU in the following modes:
“Control” in this position the MCU is in the normal operational mode, automatically controlling
the ballast discharge system if automatic control is fitted.
“Off” in this position the display is blanked and the MCU goes to a quiescent state. Although
the MCU is in a quiescent state some inputs are still monitored and logged in the internal
memory.
NOTE:
Do not attempt to service the equipment in this mode, see section 8.
“Console” in this position the MCU is in normal operational mode but manual control of the
ballast discharge system is provided from the cargo console. There will be no alarms given
and some inputs are still monitored and logged in the internal memory.