97
15.4.6 Flow overrange failure
Probable causes Action
1
Overboard discharge flowrate to
high.
Check the overboard discharge flowrate and reduce if
necessary.
2
Flowmeter not functioning
correct.
Check the connections of the related flowmeter.
Check the calibration of the related flowmeter.
Also consult section 15.12
15.4.7 Flow underrange failure
Probable causes Action
1
Flowmeter not functioning
correct
Check the connections of the related flowmeter.
Check the calibration of the related flowmeter.
Also consult section 15.12
15.4.8 Overboard arrangement failure
Probable causes Action
1
No power supply
Check the power supply to the overboard valve
actuator.
Check the signal connections between the MCU and
the valve actuator.
No air supply.
Check the air supply to the overboard valve actuator.
Check the signal connections between the MCU and
the valve actuator.
2
No air supply
Check the air supply to the overboard valve actuator.
Check the signal connections between the MCU and
the valve actuator.
Feedback switch failure.
Check the functioning of the feedback switch.
Check the connections between the MCU and the
feedback switch.
3
Feedback switch failure
Check the functioning of the feedback switch.
Check the connections between the MCU and the
feedback switch.
Overboard valve failure.
Check functioning of the overboard valve.
4
Overboard valve failure
Check functioning of the overboard valve.