Figure 63
14. After approximately 10 seconds, the signal will be given to open the overboard valve and to
close the slop tank valve. This is indicated on the display as follows:
Figure 64
15. In the case of this vessel, check that the valves have indeed been operated. On the display
of the MCU this is indicated by the change of POS: from “C” to “O”.
16. By pressing the <STOP> key, the system will return to “idle mode” and the signal to close
the overboard valve and open the slop tank valve will be given.
Figure 65
17. In the case of this vessel, check that the valves have indeed been operated.
18. Press the <CHANGE> key twice to select the “idle setup mode”.
19. Press the <NXT> key until “flowrate ind.” is selected. Use the numeric keys to enter a flow
rate of 2000 m³/h.
20. Press the <OK> key and the <BACK> key to go back to the “idle mode menu”.
CONTROL Sample point: 1 22-11-11
sample Oil type: 5 10:38
Concentration M 400 PPM discharge
Flow M 1000 m3/h dirty
Skid Flow 0 l/h com: C
Speed M 15.0 kts pos: C
Discharge rate 0.0 l/nm segregated
Total oil 0.0 l com: C
Latitude 5321.756N pos: C
Longitude 00711.854E
EPU: OK
free: 1927296 kB
MORE? STOP
CONTROL Sample point: 1 22-11-11
sample Oil type: 5 10:38
Concentration M 400 PPM discharge
Flow M 1000 m3/h dirty
Skid Flow 0 l/h com: O
Speed M 15.0 kts pos: O
Discharge rate 0.0 l/nm segregated
Total oil 0.0 l com: C
Latitude 5321.756N pos: C
Longitude 00711.854E
EPU: OK
free: 1927296 kB
MORE? STOP
CONTROL Sample point: 1 22-11-11
idle Oil type: 5 10:38
Concentration M 400 PPM discharge
Flow M 1000 m3/h dirty
Skid Flow 0 l/h com: C
Speed M 15.0 kts pos: C
Discharge rate 0.0 l/nm segregated
Total oil 0.0 l com: C
Latitude 5321.756N pos: C
Longitude 00711.854E
EPU: OK
free: 1927296 kB
? STOP SAMPLECHANGE SELFTEST